| Part No. |
Reading |
Range |
Jaw Depth
|
Force |
Std. Feeler |
| * F650 |
0.001 mm |
5 mm |
50 mm |
1.2 N |
c |
| F61101 |
0.001 mm |
1 mm |
30 mm |
2 N or 0.7 N |
6.35 mm Ø flat
Opional: 10 mm Ø flat, spherical
upper feeler convex r = 15 or r = 40,
lower feeler flat or convex r = 15 |
| * FD650 |
0.001 mm / .00005" |
10 mm / .400" |
50 mm / 100 mm optional |
0,8 - 1,1 N |
c |
| FD6200-25 |
0.001 mm / .00005" |
25 mm / 1" |
200 mm |
0,6 - 1,1 N |
c |
Some Of The Available TIPS
|
|
|
|
|
- These thickness gauges offer superb accuracy (0.010 mm / 0.0005") for fast, precise measurement of film, foil, and other sheet products.
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Force |
Std. Feeler |
| * J650/6100 |
0.01 mm |
10 mm |
50 mm / 100 mm |
0.8 N or 0.6 N |
c |
| J6200/6200-30 |
0.01 mm |
10 mm std. 30 mm optional |
200 mm |
1.5 N or 1.2 N |
c |
| JD650-10 |
0.01 mm / .0005" |
10 mm / .400" |
50 mm / 100 mm optional |
0,6 - 1,1 N |
c |
| JD650-25 |
0.01 mm / .0005" |
25 mm / 1" |
50 mm / 100 mm optional |
0,6 - 1,1 N |
c |
| * J612 |
0.01 mm |
8 mm |
12 mm |
0.8 N |
6.35 mm Ø flat std. |
| * J615 |
0.01 mm |
10 mm |
18 mm |
0.4 N |
6.35 mm Ø flat std. |
| J645 |
0.01 mm |
10 mm |
45 mm |
|
6.35 mm Ø flat std. |
|
|
|
|
|
- This handy instrument is used exclusively to measure the thickness of thin films and foils.
- The frame has the required rigidity, the insulation of the handle prevents transfer of heat from the hand of the user to the sensitive mechanical parts of the Dial Gauge.
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Force |
Std. Feeler |
| * FZ61101 |
0.00005" |
.040" |
1.18" |
2 N or 0.7 N |
6.35 mm Ø flat std.
Opional: 10 mm Ø flat, spherical
upper feeler convex r = 15 or r = 40,
lower feeler flat or convex r = 15 |
|
|
|
|
|
- The Pocket Dial Thickness Gauge KZ 615 is supplied with flat feelers 6,35 mm Ø if no other form of feelers is ordered.
- When ordering, please state whether you require another form of feelers than 6,35 mm Ø flat.
- The model KZ 615/2 differs from the model KZ 615 only by the to .800” extended measuring range.
- At rest the feelers on models KZ615 and KZ615/2 are open. Pushing the button on top of the instrument brings them together.
- The feelers are in contact when the Pocket Dial Thickness Gauges JZ615 and JZ645 are not in use.
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Std. Feeler |
Optional Feeler |
| KZ615 |
0.005" |
.400" |
.6" |
6.35 mm Ø flat |
10 mm Ø flat, convex or spherical |
| * JZ615 |
0.001" |
.400" |
.7" |
6.35 mm Ø flat |
10 mm Ø flat, convex or spherical |
| JZ645 |
0.001" |
.400" |
1.75" |
6.35 mm Ø flat |
10 mm Ø flat, convex or spherical |
|
|
|
|
|
- This handy Dial Thickness Gauge is used exclusively to measure the thickness of fibre - cement profiled sheet and other corrugated plates or irons.
- It is equipped with special feelers which have a camber of 2 mm and a width of 10 mm.
- The concentric millimetre pointer allows easy and safe reading of the Dial Thickness Gauge.
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Std. Feeler |
Optional Feeler |
| J6503WP |
0.010 mm |
20 mm |
|
r 2 mm |
none |
|
|
|
|
|
- These gauges allow accurate and fast measurement of the thickness of tube walls or other curved materials.
- They are equipped with feelers 6 mm Ø which have at their end a collar with a radius of 1 mm.
- This end collar enables tubes to be checked which still have a burr from parting.
- The ground feeler pin of 6 mm Ø is included.
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Std. Feeler |
Optional Feeler |
| JD650W |
0.010 mm / .0005" |
10 mm / .400" |
50 mm |
6 mm Ø |
none |
| J650W |
0.010 mm |
10 mm |
50 mm |
6 mm Ø |
none |
|
|
|
|
|
- This model has side discs at the lower roller for guiding the thread. Also Available w/o side discs.
- It is well suited for measuring the thickness of wires and threads, especially in continuous motion.
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Roller |
Roller |
| J650R |
0.010 mm |
5 mm |
50 mm |
8.4 mm Ø |
8.7 mm wide |
| J650/3R |
0.010 mm |
20 mm |
50 mm |
8.4 mm Ø |
8.7 mm wide |
| K6100R |
0.100 mm |
10 mm |
100 mm |
8.4 mm Ø |
8.7 mm wide |
| J6200R |
0.010 mm |
10 mm |
200 mm |
8.4 mm Ø |
8.7 mm wide |
| F650R |
0.001 mm |
5 mm |
50 mm |
8.4 mm Ø |
8.7 mm wide |
| JD650R |
0.010 mm / .0005" |
10 mm / .400" |
50 mm |
8.4 mm Ø |
8.7 mm wide |
| JD6100R |
0.010 mm / .0005" |
10 mm / .400" |
100 mm |
8.4 mm Ø |
8.7 mm wide |
| FD650R |
0.001 mm / .00005" |
10 mm / .400" |
50 mm |
8.4 mm Ø |
8.7 mm wide |
|
|
|
|
|
- For big projects.
- Can be purchased with a 300 mm jaw depth and 50 mm measuring range
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Std. Feeler |
Optional Feeler |
| K650/5JD650W |
0.100 mm |
50 mm |
50 mm |
c |
none |
|
|
|
|
|
- This is a K650 with pressure lever.
- Model K650 with lifting device has the same technical specification as model K650 with pressure lever. At rest the feelers are closed.
- This style (with lifting device) has the advantage that the contact pressure of 0,5 N is applied independently of the user.
|
| Part No. |
Reading |
Range |
Jaw Depth
|
Std. Feeler |
Optional Feeler |
| * K650 |
0.100 mm |
10 mm |
50 mm |
c |
a,b,d, or e |
|
|
|
* *
|
- This Stand (62.1670) converts the Dial Thickness Gauges K650, K6100, J650, J6100 and F61101/30 as well as the respective digital models, designed for hand-held use, to table models.
|
|
|
|
|
|
- The well thought-out design, accurate components and robust construction of our Precision Dial Gauge series offer reliability, durability and long working life.
- The standard features that enhance the quality across this entire product offering are:
- Calibrations of all Dial Gauges are traceable to national and international standards.
- The final quality control for this whole series includes visual inspection and full mechanical functions' tests.
- To eliminate lateral play and resultant errors each measuring spindle is carefully matched to its stem.
- The bezel together with the outer dial can be rotated through full 360° to set zero in any position.
- The zero position is factory set at 12 o'clock after an allowance of a minimum of 0,1 mm pre-travel from spindle end stop.
- Adjustable tolerance markers to set tolerance limits.
- Standard measuring tip with Ø 3,175 mm steel ball and M 2,5 thread.
- A range of special tips available as options.
- Standard stem of Ø 8 mm h 6.
- Materials and components selected specifically to ensure a long working life.
* stock items
|
|